
A spoken tutorial contains bursts of energy separated by quieter regions. A steady laboratory sine wave would miss that contrast, so this fixture uses a modulated harmonic signal. Here is what happens to a speech-shaped test signal when we vary rms and peak normalization and inspect the resulting samples.
Build a controlled signal
Peak normalization and RMS normalization target different statistics. A sparse transient can have a high peak but low average energy, making the distinction especially important. The fixture lasts 0.8 seconds, uses a 48,000 Hz sample rate and starts with a 165 Hz fundamental plus two harmonics. Its original peak is scaled to 0.84 of full scale. That gives each setting the same starting point across 38,400 samples per channel.
Three runs on the same input
| Setting | Sample peak (dBFS) | RMS (dBFS) | At digital rail (%) |
|---|---|---|---|
| Original | -1.51 | -11.76 | 0.00 |
| Peak −1 dBFS | -1.00 | -11.25 | 0.00 |
| RMS −16 dBFS | -5.75 | -16.00 | 0.00 |
The move from Original to RMS −16 dBFS changed RMS by 4.24 dB. At the final setting the peak was -5.75 dBFS and RMS was -16.00 dBFS. The gap describes how far the sample peak sits above the average energy for this particular clip. It does not include gain changes later in a player or operating system.
Read the envelope and then listen
Each row below spans the same 0.8 seconds. Within each horizontal slice, the line extends from the minimum to the maximum sample. That preserves brief peaks which would disappear if we drew only one sample for each screen pixel. The chart shows the left channel where a variant produces stereo output.

Use the result in a voice recording workflow
Test separately with a real voice recorded at the planned microphone distance. Synthetic harmonics cannot reproduce consonants or room noise. Export the same passage at the settings you are considering and compare it with processing bypassed. Keep monitoring volume fixed for a peak test, or loudness-match the clips if the question is timbre. Those are different listening experiments.
Record the source level, output format and whether any later limiter or normalization was active. These measurements use sample peaks and unweighted RMS. They describe a digital signal, not sound pressure at the listener’s ear, perceptual loudness in LUFS or the peak that a particular reconstruction filter may produce.
Sources and further reading
Cover photograph: Microphone and stand at Audio Mix House, Studio B (13430490054) by Audio Mix House from United States. CC BY 2.0. Cropped and typeset for this cover. The photograph illustrates the topic.
